Bathroom & Kitchen Zones

Bathrooms and kitchens have special rules under BS 7671. Water and electricity are a lethal combination — the regulations define zones that restrict what can be installed where.

Bathroom Zones

Bath/ShowerZone 0Inside fitting only. IPX7.Zone 1IPX4 min.Zone 2IPX4 min.
ZoneLocationIP RatingSockets
Zone 0Inside bath/showerIPX7No
Zone 1Above bath, up to 2.25mIPX4No
Zone 20.6m outside Zone 1IPX4No (shavers: SELV only)
Outside zonesRest of bathroomYes (shaver socket only)

No standard 13A sockets are permitted anywhere in a bathroom.

Kitchen Rules

All electrical work in a kitchen is notifiable. Additional rules:

  • Sockets must be at least 300mm horizontally from a sink
  • Any socket within reach of a water source should be on an RCD-protected circuit
  • Underfloor heating, extractor fans, and cooker circuits must be notifiable

Part P Reminder

Any electrical work in a bathroom or kitchen is notifiable under Part P — even replacing a like-for-like fitting. Always use a registered electrician or notify building control.